CVE-2026-42971
Medium · 5.5CVSS
5.5
EPSS
0.5%
Published
Jun 9, 2026
CISA due date
—
Cloudanix analysis
A person who can already sign in to an affected Windows computer may be able to view sensitive information they should not be able to access.
- Exploitation
- Local Privilege
- Attacker needs
- Low Privilege
- Complexity
- Low
- Impact
- Data Exposure
- Component
- Network Service
- Class
- Information Disclosure
- Remediation
- Patch
- Effort
- Low
- Patch risk
- Low
What it actually does
CVE-2026-42971 is a local information disclosure vulnerability in Windows Push Notifications caused by use of an uninitialized resource. A locally authenticated attacker with low privileges can trigger the vulnerable code path and cause sensitive data from memory or another local resource context to be exposed. The vulnerability does not provide remote code execution, privilege escalation, integrity modification, or denial of service by itself, but the confidentiality impact is high because disclosed data may include information useful for follow-on compromise.
Why it matters to the business
An attacker who already has local access to a Windows workstation or server could extract sensitive information that may help them move further through the environment, steal tokens or secrets if exposed, or improve later attacks. The issue affects many supported Windows client and server versions, including Windows 10, Windows 11, Windows Server 2016, 2019, 2022, and 2025, so patching may require broad endpoint and server coverage. Current public exploitation indicators are low: EPSS is approximately 0.46%, flat over 30 days, there is no CISA KEV listing, no ransomware association, and no known exploit maturity reported; however, local information disclosure bugs are still valuable after an attacker gains an initial foothold.
How an attack unfolds
An attacker first obtains local authenticated access to an affected Windows system, such as through stolen credentials, malware execution, abuse of an existing user session, or access as a low-privileged user. The attacker then invokes or interacts with the Windows Push Notifications components in a way that reaches the vulnerable uninitialized-resource handling path. Because the resource is not properly initialized before use, the attacker can cause data that should not be exposed to be returned or made observable from the local context. The attacker analyzes the disclosed information for secrets, memory contents, application data, identifiers, or environmental details that can support credential theft, session hijacking, lateral movement, or more targeted exploitation. This flaw is most likely to be chained with other vulnerabilities or post-compromise tooling rather than used as a standalone initial-access technique.
How to fix it
Apply the Microsoft security update or latest cumulative update that addresses this vulnerability for all affected Windows versions. Prioritize internet-facing servers, shared workstations, virtual desktop infrastructure, administrator workstations, and systems where untrusted users can log on locally. Because no exact fixed build numbers were provided in the input, validate remediation against Microsoft Security Update Guide entries and the installed cumulative update level for each Windows release. If immediate patching is not possible, reduce risk by limiting local logon rights, removing unnecessary interactive access, enforcing least privilege, hardening endpoint controls, monitoring unusual local process activity, and preventing untrusted users from executing arbitrary code on affected systems. There is no reliable configuration-only mitigation that should be considered equivalent to patching.
How to confirm the fix worked
Confirm that each affected Windows asset has installed the relevant Microsoft cumulative/security update released for this vulnerability or a later superseding update. Use enterprise patch management, endpoint inventory, or PowerShell-based checks such as querying installed hotfixes and OS build numbers, then compare results with Microsoft’s official fixed build guidance for the specific Windows release. Verify coverage across Windows 10 1607, 1809, 21H2, 22H2; Windows 11 23H2, 24H2, 25H2, 26H1; and Windows Server 2016, 2019, 2022, and 2025 where present. For exposure validation, identify systems where local interactive logon is allowed for non-administrative users and where Windows Push Notifications services/components are present. A successful fix should show the applicable update installed, the OS build at or above the fixed level, and no remaining unpatched affected Windows versions in vulnerability or asset inventory tooling.
Typical attack path
- Gain local authenticated access to an affected Windows client or server.
- Execute code or commands as a low-privileged local user.
- Interact with Windows Push Notifications functionality to trigger the vulnerable uninitialized-resource code path.
- Collect the disclosed local information.
- Analyze the recovered data for credentials, tokens, memory fragments, configuration details, or other sensitive context.
- Use any useful information to support privilege escalation, lateral movement, persistence, or data access through separate techniques.
How to detect it
There are no public, vulnerability-specific indicators of exploitation provided for this issue, and local information disclosure exploitation may leave little or no direct evidence. Detection should focus on post-compromise behavior before and after the likely trigger. Review endpoint detection telemetry, Windows Security logs, Sysmon if deployed, PowerShell logs, and application/service logs for unusual local execution by low-privileged users, suspicious tooling launched from user-writable directories, unexpected interaction with Windows notification components, and subsequent credential or discovery activity. Useful log sources include Windows Security process creation events, Sysmon process and image-load telemetry, PowerShell Script Block logs, EDR file/process/network timelines, Windows service control activity, and authentication logs showing anomalous local or remote logons after suspected exposure. Hunt for sequences where a non-administrative user executes unfamiliar binaries or scripts, interacts with notification-related Windows services, and then performs credential access, enumeration, remote logon attempts, or lateral movement. Since no KEV listing, ransomware use, known threat actor exploitation, or public exploit maturity is reported, absence of specific indicators should not be treated as proof of no exploitation; rely on behavioral investigation and endpoint timelines.
What your security team should do
- Patch affected Windows endpoints and servers through the normal cumulative update process, prioritizing systems with broad user access, administrator use, or high-value data exposure.
- Use asset inventory to identify all affected Windows versions and track remediation to complete coverage, not just internet-facing systems.
- Treat this primarily as a post-compromise data exposure risk and ensure EDR visibility is enabled for local process creation, suspicious script execution, and credential-access behavior.
- Review and restrict local logon rights, especially on servers and administrative workstations.
- Monitor for suspicious local activity around Windows notification components, especially execution by unusual parent processes or by recently created low-privileged accounts.
- Because EPSS is low, flat, and there is no KEV listing or known exploit maturity, prioritize according to standard Windows patch cadence unless the system allows untrusted local users or handles highly sensitive data.
- Investigate any endpoint alerts that combine local information-gathering behavior with credential theft, token access, or lateral movement, as this vulnerability is most useful when chained with other techniques.
The record
Use of uninitialized resource in Windows Push Notifications allows an authorized attacker to disclose information locally.
Affected packages
| Ecosystem | Package | Introduced | Fixed |
|---|
Related vulnerabilities
- CVE-2026-114657 Grav from 2.0.0 before 2.2.5 contains an information disclosure vulnerability that allows… CWE-200
- CVE-2026-114574 A security vulnerability has been detected in massCodeIO massCode 5.10. CWE-200
- CVE-2026-111756 follow-redirects is a Node.js HTTP and HTTPS client wrapper that automatically follows… CWE-200
- CVE-2026-111755 follow-redirects is a Node.js HTTP and HTTPS client wrapper that automatically follows… CWE-200
- CVE-2026-112091 A flaw has been found in Dav-ee dairy-management-system… CWE-200
- CVE-2026-109259 ImageMagick before 6.9.13-57 and 7.x before 7.1.2-32 contains an uninitialized memory… CWE-200
- CVE-2026-107383 MariaDB Connector/Node.js is used to connect applications developed on Node.js to MariaDB… CWE-200
- CVE-2026-106120 LiquidJS is a Shopify / GitHub Pages compatible template engine in pure JavaScript. CWE-200