CVE-2026-34021
NoneCVSS
—
EPSS
0.3%
Published
Jun 15, 2026
CISA due date
—
The record
The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.
Affected packages
| Ecosystem | Package | Introduced | Fixed |
|---|
Related vulnerabilities
- CVE-2026-87952 Authentication Bypass by Capture-replay vulnerability in Drupal SAML SSO - Service… CWE-294
- CVE-2026-88278 GeoVision GV-LPC2211 V1.13 fails to enforce WS-Security UsernameToken freshness or nonce… CWE-294
- CVE-2026-55250 Maravel, a PHP framework oriented towards dependency injection, prior to version 10.74.0… CWE-294
- CVE-2026-73312 XenForo before 2.3.13 contains a refresh token replay vulnerability that allows attackers… CWE-294
- CVE-2026-73311 XenForo before 2.3.13 contains an OAuth2 authorization code reuse vulnerability that… CWE-294
- CVE-2026-86219 Authen::SASL::Perl::DIGEST_MD5 versions before 2.2100 for Perl accept replayed… CWE-294
- CVE-2026-53636 Open edX Platform enables the authoring and delivery of online learning at any scale. CWE-294
- CVE-2026-12704 When SAML IdP-initiated login is enabled in Grafana Enterprise, the SAML library skips… CWE-294